The inverter logs an event saying time synchronization failed because it could not get time information from the configured NTP server. On SMA inverters this shows up as event 10110, and some documents list the same NTP explanation under event 10114. The manufacturer's corrective steps are to check that the NTP server is configured correctly and that the inverter sits on a local network with Internet access. Because of these steps, a wrong NTP server setting or a missing network or Internet connection are the likely causes to check first. On meters that use SNTP, the internal clock syncs to an NTP server, and SNTP serves as a secondary time source. In unicast mode, the meter queries a primary or backup NTP server at a set rate and switches to the other server if no reply arrives within the timeout. A successful sync sets a status bit for the primary or the backup server, so if neither bit is set, the meter is not synchronized.