Loose or corroded terminals

ID
meas:jbox-terminal-corrosion
IRI
https://solarlattice.org/kb/meas/jbox-terminal-corrosion
Status
active
Also known as
Bad contacts

During junction box inspection, this signature shows up as terminals, wire attachments or lids that are loose, oxidised or corroded. Inside the box you may find parts that are disconnected, broken, burned or corroded, and the potting material can hide the fault until it is removed. Bad or corroded contacts raise the internal resistance and heat the junction box, so an infrared camera can show the box as a hotspot. In an IR survey, a wire connection that is clearly hotter than the wire itself should be checked for a loose or corroded contact. Corrosion usually follows moisture getting into a damaged or detached box, for example through a cracked housing or a missing seal at the wire entrance. Mechanical contacts can work loose through day-night and seasonal thermal cycling. This pattern points to junction box interconnection failure or junction box failure, which can lead to power loss, open or short circuits, internal arcing and fire. A junction box that runs hotter than its neighbours can mean a cold solder joint with raised contact resistance.

Claims

temperature_rise

c1 drafted · lead 5–10 K

Conditions: Open-circuit substrings or module strings caused by unreliable (cold solder) connections in separated junction boxes, compared with active strings during IR thermography

Refers to open-circuit substrings that result from bad junction box connections, not to the terminal itself.