Solar Lattice

Measurement

High open-circuit voltage

ID
meas:high-voc
IRI
https://solarlattice.org/kb/meas/high-voc
Status
active

This signature is a string open-circuit voltage reading that comes out higher than the value expected for that string. Measure each string's open-circuit voltage with suitable test equipment before any switches are closed or string overcurrent protection is fitted. To judge the reading, compare it with a value worked out from the module datasheet or a PV model that accounts for module type, module count and cell temperature. You can also measure one module and scale up to the full string, or, where strings are identical, compare strings with each other. A reference string with its own meter helps when irradiance is unstable. High readings usually come from wiring errors, such as the wrong number of modules connected in series in the string. Open-circuit voltage can also be read from a string I-V curve trace, which gives short-circuit current and fill factor at the same time.