Normal fan supply voltage

ID
meas:fan-supply-voltage-normal
IRI
https://solarlattice.org/kb/meas/fan-supply-voltage-normal
Status
active

The check usually follows an external fan alarm (ExtFanErr), which the inverter raises when it detects that a cooling fan has failed. Listed causes of that alarm include a blocked fan, a fan past the end of its service life, and poor contact at the fan socket connector. Suggested first steps are to watch for about 5 minutes to see if the alarm clears by itself, check the fan blades for foreign objects, and then switch off the 3-phase supply and reboot. A failed fan is one of the known reasons an inverter overheats and reduces its output because of temperature. To reach the fan, its connector and the power supply connector are unplugged inside the inverter tray.