Low intermediate circuit voltage

ID
meas:dc-bus-voltage-low
IRI
https://solarlattice.org/kb/meas/dc-bus-voltage-low
Status
active
Also known as
PV POWER LOW, LOW PV POWER, Power low

The inverter reports that its intermediate circuit (DC link) voltage is too low to keep feeding power into the grid, or has fallen below the allowed threshold for feed-in. On Fronius inverters this shows up as status code 306, where the inverter briefly stops feeding the grid and goes back to the startup phase. Code 306 clears by itself and appears every morning and evening because irradiance is low; at those times it does not indicate a fault. Check whether the code keeps coming back while there is plenty of sunlight; if it does, call the system installer. Fronius code 443 is a related reading: the intermediate circuit voltage is too low or unsymmetrical, and the inverter stops feeding current into the grid. If code 443 persists, contact a Fronius-trained service technician.

Signals

Monitoring channels where this signature appears, named by SunSpec model point.

PointUnitPattern
model_103.DCVVDC voltage low or falling, typically at dawn and dusk
model_103.DCWWDC input power too low to sustain feed-in