Equipotential bonding means electrically joining conductive parts, such as mounting racks and module frames, so they stay at the same potential. In a PV system, parts that need bonding should be connected to a central equipotential panel provided for that purpose. Do not use the inverter enclosure as the bonding point. SMA warns that bonding done wrong can damage the inverter, and that this damage is not covered under warranty. Where protective earthing or bonding conductors are installed on the DC side, run them parallel to the DC cables and bundle them together. During commissioning, test the continuity of all such conductors and check their connection to the main earthing terminal. Metallic support structures need identified bonding jumpers between separate sections, and they connect to the equipment grounding conductor. Good bonding also matters for electromagnetic compatibility. In lightning protection, potential equalization ties grounded media together at ground, roof and intermediate levels.

<!-- review notes

Claims

related_to

c1 drafted · lead Mounting structure

Mounting racks are named as components that may need equipotential bonding. Metallic support structures need identified bonding jumpers between separate sections.

c2 drafted · lead Module frame

Module and array frames are named as parts that are bonded.

c3 drafted · lead Electromagnetic compatibility

Solis says proper grounding and equipotential bonding are critical for EMC performance.

c4 verified · fact IEC 62548 proposed

Array frame bonding arrangements are to be specified and installed to IEC TS 62548:2013.

verified by: review-workflowverified on: 2026-10-24