PV ground fuse
The PV ground fuse is the fuse that protects the solar module ground path in Fronius Galvo inverters. A defective ground fuse can trigger status code 472, and the inverter then stops feeding energy into the grid. Status code 551 reports the same defective fuse, but only as a warning on the display. The fix is to replace the ground fuse. If the code keeps coming back, contact the system installer. In the Galvo ground settings, the ground mode can be off, positive or negative. When the array is grounded, ground monitoring can be set to warning, error, or both. To get a proper ground connection, tighten all three GND ground terminals to the specified torque during installation.